Argus AAD
-
Argus AAD Battery Replacement
Note: Video states a 1-year replacement period for Argus batteries, but the manufacturer has since changed its requirement to every repack, 500 jumps or Batt Low reading.
Two CR123A Lithium batteries are to be replaced every repack, every 500 jumps or when the unit displays Batt Low or Batt Rpl.
Unscrew Phillips head closing screw. Remove old batteries. Insert new batteries noting the polarity marks on the outside of the unit. Re-install battery back plate and tighten closing screw to snug.
Continue reading -
Argus Ruggedized Kit Installation
The Argus Ruggedized Kit consists of a black metal face plate, stainless steel button and super glue. This kit protects LCD display screen against routine knocks to the display from use, packing or transportation.
12 small dots of super glue are placed around the outside edge of the face of the unit. 5 along top, 5 along bottom and 1 on each side.
The button is centered on the logo, where the current press-button is located. No super glue is used to hold the button in place.
Continue reading -
Overview of Argus Operations
The Argus is manufactured by Aviacom in Belgium. It has three parts: Processing Unit, Cutter and Control Unit. The Argus turns on with 4 button pushes. The first wakes it up, which is followed by a HELLO. The Logo, ARG and US will then flash in sequence. As each part flashes, press the button. If you are too fast or slow with the flash sequence, it will turn back off with a Bye Bye. The unit will give the status on 3 checks during startup: Battery, Cutter and System. A check mark indicates each part is in working order. An error will be shown followed by a shut-off. If everything is in working order, the unit will show the current mode. The unit is on for 14 hours before the automatic shut-off, or you can manually turn it off before 14 hours. Continue reading -
Argus Menu Item: Config
With the unit on, press the button twice and select the Menu option and then Config option. Items under this menu item include: Alt Unit (Meters or Feet), Sys Unit (Metric or U.S.), Time Cfg (time and date settings), Log Mode (Normal or Trace). Confirm after changing the altitude, system or log mode. The date and time updates are completed when you finish with entering the year. Continue reading -
Argus Cutter & Display Replacement
Both the display and cutter are secured through a screw-on connection. The cutter has a 3-prong connection. The display has a 4-prong connection. Once the new cutter and/or display has been installed, turn on unit to verify the Argus unit passes the systems checks. Continue reading -
Argus Menu Item: Info
With the unit on, press the button twice and select the Menu option and then Info option. Select Jump for info on your skydives and Admin for info on your unit. Jump: Jump info such as number of jumps, last freefall time, total freefall time, vertical speed, temperature, barometric pressure and the number of times the unit has fired. Continue reading -
Argus Menu Item: Modes
How to change the mode on an Argus AAD. Mode Sel: With the unit on, press the button twice and select the Menu option and then Modes option. Select Mode Sel option and choose from Standard, Novice, Tandem or Swoop. Press the button at the appropriate mode you want to use. Follow that by pressing the button when Confirm is shown. Wait several seconds for the unit to display the mode you selected. If the proper mode is selected, then it is ready to use. If not, repeat the process until you’ve selected the correct mode. Firing Altitude & Speeds for the 4 modes.- STD: 820 ft/78 mph
- NOV: 1000 ft/45 mph
- TAN: 2200 ft/78 mph
- SWOOP 820 ft/78 mph/Standby upon parachute opening.
-
Argus: Filters, Screw and Ring
One filter is located on the inside on the battery back plate. A second filter can be installed on the outside of the battery back plate for swoopers who may get the unit wet on a regular basis. To replace the filter, pick the old filter off and stick the new filter on. The filter or filters must be replaced after getting wet and/or damaged. Once a filter is removed, it can not be used again. The closing screw is a small Phillips head screw that secures the back plate to the Argus unit. It should be snug/hand tight. Continue reading -
Argus Cutter Service Bulletin Revised
Aviacom has issued a revised service bulletin for a mandatory replacement of all Argus cutters manufactured August 2007 and earlier. The bulletin says the cutter is to be replaced "at the next repack but no later than 31 December 2010." Previously the service bulletin said the cutter had to be replace before the next jump, the company said that wording was in error and released the revision. Continue reading